logo

Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room

1 zestaw
MOQ
Negocjowalne
Cena £
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room
cechy Galeria opis produktu Poprosić o wycenę
cechy
specyfikacje
Ciśnienie przechowywania: 4.2mpa
Czas oprysku: ≤10s
gęstość wypełnienia: ≤1420kg/m3
Ciśnienie nominalne: 5,3 MPa
Presja testowa: 8,4 MPa
Siła robocza: Prąd stały 24 V 1,6 A
Temperatura pracy: 0 ℃ ~ 50 ℃
Zasięg strefy chronionej:: Proporcja: ≤800m² Objętość: ≤3600m³
Tryb uruchamiania: Automatyczny, Elektryczny Ręczny, Mechaniczny Ręczny
Objętość cylindra: 40L, 70L, 100L, 120L, 150L, ​​180L
Podkreślić:

0℃~50℃ Working Temperature Novec 1230 Fire Suppression System

,

≤800m² Protected Zone Clean Agent Fire Suppression System

,

40L-180L Cylinder Volume Novec1230 Fire Suppression System

Podstawowe informacje
Miejsce pochodzenia: CHINY
Nazwa handlowa: Air Giant
Orzecznictwo: CAL,CMA,CNAS,ILAC-MRA,CCC
Numer modelu: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Zapłata
Szczegóły pakowania: Sklejka zewnętrzna z torby lub papieru z bąbelkami
Czas dostawy: 10-15 dni roboczych
Zasady płatności: L/C, D/P, T/T, Western Union, PayPal, karta kredytowa
Możliwość Supply: 28000 zestawów tygodniowo
opis produktu

Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room

 

Description


The molecular formula of perfluorohexanone Novec1230 is CE3CF2C (O) CF (CE3) 2, and the relative molecular weight is 316.04. It is a clear, colorless, slightly odorous, and easily gasified liquid fire extinguishing agent at room temperature, which is not a dry hazardous substance and does not leave residue after release. The fire extinguishing agent is neither dry HFC nor inert gas. It is a new halon substitute and has made breakthrough progress in halon substitute field.

 

Novec1230 gas fire extinguishing agent does not contain bromine and chlorine elements, and does not damage the body oxygen layer after fire extinguishing, and its body oxygen consumption potential value is zero. At the same time, more importantly, unlike hydrofluorocarbon fire extinguishing agent, Novec1230 has a very low greenhouse effect potential value, GWP=1 is equivalent to CO2, and Novec1230 has a short life in the atmosphere, only 3-5 days, so it fundamentally solves the environmental pollution caused by halon fire extinguishing agent and hydrofluorocarbon fire extinguishing agent.

 

Novec1230 is environmentally friendly, safe for personnel, non-conductive, does not leave residue after fire extinguishing, does not damage equipment, and has excellent fire extinguishing performance. Therefore, it is a green environmental protection fire extinguishing agent designated by its name and its application range is wide.

 

Working Principle
 

Here is the illustration of working principle to whole system.


 
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 0

 
 
Application
 

As its name says, the single zone pipe network Novec1230 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network Novec1230 fire suppression system can be used to protect some large and also significant places, such as the followings:

 

- Computer rooms

 

- Telecommunication center

 

- Facilities underground

 

- Offshore oil extraction

 

- Library

 

- Data and paper archives

 

- Valuable article storage

 

- Power generator storage room


Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 1

 
Advantages


It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.

1. Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinde.

2. Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.

 


 
Packages
 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
 
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 2


Polecane produkty
Skontaktuj się z nami
Osoba kontaktowa : Mr. Missaya Lu
Tel : +86 188 1945 1181
Pozostało znaków(20/3000)